MODEL NO: 876T26, 874T26

Rheem Metro 26L Gas Continuous Flow Water Heater

10

YEAR
WTY

Rheem Metro 26L Gas Continuous Flow Builder models are the right choice for your projects. They guarantee hot water that never runs out, with quality and performance to add value and peace of mind.

Features at a Glance

Capacity (L)
26
No. of People
4-5
Energy Rating
6

To install a Rheem, you'll need a plumber

Get in touch with your local Rheem Approved Plumber and ensure your install is done right.

  • 26 L/minute continuous hot water delivery (at 25°C rise) - suitable to 2-2.5 bathrooms
  • Compact 520mm(H) x 355mm(W) x 187mm(D)
  • Flamesafe® overheat protection — shuts down the water heater before overheating can occur
  • Rheem Q Factor™ — ensures rapid hot water every time, with none of the fluctuations that occur with some continuous flow units
  • Remote temperature controller options — so you can set the best and safest temperature for the bathroom and kitchen
  • Extra safety — 50°C temperature limited models available
  • 60° C hot water for kitchen and laundry - where 50 or 55° C is often not hot enough (Model: 874T26)
  • Natural gas and propane models available
  • 10 year warranty on heat exchanger*
  • 10 Years parts and 3 Years labour on Heat Exchanger
  • 3 Years parts & labour on other components, when installed in a domestic dwelling.
  • For all other installations, the warranty period is 1 Year parts and labour on Heat Exchanger and other components.

See the Rheem warranty set out in the Owner's Guide and Installations Instructions.

To obtain a quote on this product

Call Rheem on


Ready to buy a Rheem?

For help to make the right choice, access our network of Rheem Approved Plumbers and Stockists.


Top Five Troubleshooting Topics


Please see the Owner Guide for your Heat Pump model.

For showers to operate correctly, it’s necessary to store your hot water at a minimum of 60°C. 

 

If your water heater is fitted with a temperature limiting valve and the water is hotter than it should be, please call Rheem on 1300 556 036.  

 

If your hot water is hotter than it should be and you don’t have a temperature limiting valve installed, then you could:

  • Have the thermostat on your water heater adjusted downward (with a gas storage water heater you can do this yourself). Please note that gas storage must be set no lower than 60°C and a gas continuous flow booster for a solar system must be set no lower than 70°C

     
  • Ask your plumber to install a 50°C temperature limiting valve

 

To find your local Rheem Plumber, contact us  or call Rheem on 1300 556 036.  

Please see the Owner Guide for your Storage Water Heater model and our gas relighting videos. 

Please see the Owner Guide for your Storage Water Heater model and our gas relighting videos. 

Please see the Owner Guide for your Storage Water Heater model.


Is the gas connection only used for the Water Heater?

Please, select all the fields

Running Cost Estimator Disclaimer as at 23/10/2017

Things that you should know about the Rheem Running Cost Estimator

The estimator is provided as a guide only to help you compare estimated running costs between various water heater types.

The estimator is based on Australian Standard AS5263, which relies on certain assumptions, such as an average daily load of 200L and 19 tap turns. Your situation and usage may be different to these assumptions, so the estimator may not match your actual daily loads and pattern of use.

Accordingly, the estimator cannot and does not purport to provide an accurate assessment of your yearly hot water energy bill. It does, however, allow a reasonable comparison between various water heater types based on Australian Standard AS5263 and average fuel tariffs used in the estimator.

Your state has been used to determine the temperature rise required to heat water from cold to a temperature of 65C, the applicable charge for the tariff type selected and the amount of solar savings.

Solar savings are based on Australian Government approved modelling for the type of solar water heater selected and the booster type. All electric boosted solar water heaters are modelled with a continuous tariff, but may be suitable for use on other tariff types depending on the model selected, your climate zone and the amount and usage pattern of hot water use.

Tariffs are current as at 1st July 2017 and represent an average price for the fuel type for the capital city in the state or territory, including GST.

Fixed charges, system access charges, delivery fees and any other fees and charges, including special rates and discounts are excluded from the estimator.

Energy consumption figures used are for a typical water heater within a category and do not reflect a specific model. Actual energy use may vary.

Heat Pump and solar water heaters may be suitable for Off Peak/Shoulder Rate tariffs depending on the type of water heater selected and the location. You should consult with your energy provider or installer before making any decision.

Continuous Flow Brochure 2018


Rheem 27L Gas Continuous Flow Water Heater

Hot water that never runs out. Rheem 27L is our highest capacity continuous flow gas water heater.

Rheem 27L Internal Gas Continuous Flow Water Heater

Hot water that never runs out. Rheem 27L internal is our highest capacity gas continuous flow gas water heater.

Save when switching to solar


To install a Rheem, you'll need a plumber

Get in touch with your local Rheem Approved Plumber and ensure your install is done right.


Ready to buy a Rheem?

For help to make the right choice, access our network of Rheem Approved Plumbers and Stockists.