MODEL NO: 800170

Rheem Indoor 170L Gas Water Heater

10

YEAR
WTY

Suitable for indoor installations the Rheem Indoor Gas 170L is an easy replacement for most existing 3 Star internal models and provides service to multiple taps at once without losing hot water pressure. Rheem Indoor 170L is rated at 2.8 Stars

Features at a Glance

Capacity (L)
170
No. of People
3-5
Energy Rating
2.8

To install a Rheem, you'll need a plumber

Get in touch with your local Rheem Approved Plumber and ensure your install is done right.

  • Mains pressure for hot water from multiple taps at the same time
  • Reduced replacement costs an easy to install replacement for most existing 3 Star models
  • Natural gas model
  • Star rating: 2.8 Stars
  • Made in Australia
  • 10 year on cylinder warranty*
  • 1 year labour warranty on cylinder*
  • 1 year parts & labour warranty on all other components, for domestic (non-commercial) installations*

*Warranty conditions apply

To obtain a quote on this product

Call Rheem on


Ready to buy a Rheem?

For help to make the right choice, access our network of Rheem Approved Plumbers and Stockists.


Top Five Troubleshooting Topics


Please see the Owner Guide for your Solar Hot Water System model.

The flow of hot water is not adequate to keep the water heater operating. This can be caused by flow restrictors and water saving low flow taps. You’ll need to have a plumber increase your hot water flow rate to a minimum of two to three litres per minute. To find your local Rheem Approved Plumber, contact us  or call Rheem Service on 1300 556 036.  

The error code is displayed in the room temperature display. Please refer to the below listing to see what your error codes means, then call Rheem Service to book a service call on 13 10 31.

 

Error Code

Fault Condition

Action

03

Filter damage

 

 

 

 

 

 

BOOK SERVICE CALL WITH RHEEM SERVICE

PH: 13 10 31

05

Filter not cleared

11

Ignition Failure

12

Flame Failure

14

Thermo Switch Off (150⁰C)

Overheat Thermistor temp. too high

16

Room temp. too high

(40⁰C  10 min)

22

Tip-Over switch operate

31

Room temp. thermistor abnormal

33

Overheat thermistor abnormal

62

Abnormal fan speed

71

Gas solenoid valves circuit abnormal

Gas proportional control valve circuit abnormal

72

Detected false flame

Thermocouple circuit abnormal

73

Functional trouble on gas type circuit

 

 

H: High

L: Low

SW: Switch

Your local Rheem Plumber will pinpoint your ideal hot water system. They can supply Rheem products for a very competitive price and install them for you too. Another way to find the right hot water system for your home is to use our handy Help Me Decide tool

The water temperature may be lower than usual due to heavy hot water usage. Also, this problem could be due to faulty tempering valve that is excessively cooling your hot water. Your local approved Plumber can test your system and replace the valve if necessary. To find your local Rheem Plumber, contact us  or call Rheem on 1300 556 036.  

Do you have a solar water heater? Check that the booster is being used as per the installation instructions for your model. If you have a timer installed, you will need to ensure that sufficient time is allowed to heat enough water to meet your household’s hot water needs

If you have a 50°C temperature limited water heater, then hot water to your whole house will be limited to 50°C


Is the gas connection only used for the Water Heater?

Please, select all the fields

Running Cost Estimator Disclaimer as at 23/10/2017

Things that you should know about the Rheem Running Cost Estimator

The estimator is provided as a guide only to help you compare estimated running costs between various water heater types.

The estimator is based on Australian Standard AS5263, which relies on certain assumptions, such as an average daily load of 200L and 19 tap turns. Your situation and usage may be different to these assumptions, so the estimator may not match your actual daily loads and pattern of use.

Accordingly, the estimator cannot and does not purport to provide an accurate assessment of your yearly hot water energy bill. It does, however, allow a reasonable comparison between various water heater types based on Australian Standard AS5263 and average fuel tariffs used in the estimator.

Your state has been used to determine the temperature rise required to heat water from cold to a temperature of 65C, the applicable charge for the tariff type selected and the amount of solar savings.

Solar savings are based on Australian Government approved modelling for the type of solar water heater selected and the booster type. All electric boosted solar water heaters are modelled with a continuous tariff, but may be suitable for use on other tariff types depending on the model selected, your climate zone and the amount and usage pattern of hot water use.

Tariffs are current as at 1st July 2017 and represent an average price for the fuel type for the capital city in the state or territory, including GST.

Fixed charges, system access charges, delivery fees and any other fees and charges, including special rates and discounts are excluded from the estimator.

Energy consumption figures used are for a typical water heater within a category and do not reflect a specific model. Actual energy use may vary.

Heat Pump and solar water heaters may be suitable for Off Peak/Shoulder Rate tariffs depending on the type of water heater selected and the location. You should consult with your energy provider or installer before making any decision.

Rheem Range Brochure 01 March 2019

Rheem Indoor 135L Gas Water Heater

The Rheem Indoor Gas 135L is suitable for indoor installations and an easy replacement for most existing 3 Star models.

Save when switching to solar


To install a Rheem, you'll need a plumber

Get in touch with your local Rheem Approved Plumber and ensure your install is done right.


Ready to buy a Rheem?